LP1 - Tunable Laser Photoacoustic Gas Analyzer

LP1 - Tunable Laser Photoacoustic Gas Analyzer

The LP1 combines the high selectivity of tunable laser spectroscopy with the unmatched sensitivity and linearity of the patented cantilever enhanced photoacoustic technology. This zero-background technique gives high stability with re-calibration period of several months. These unique features make the LP1 an ideal choice for low-ppb level monitoring in demanding environments. Wide range of infrared active gases can be monitored with the LP1. It can be equipped with one or two laser sources.

 

The cell is operating in non-resonant mode, and therefore, the signal from two laser sources can be measured simultaneously using different modulation frequencies.The photoacoustic signal level is directly proportional to the target gas concentration in the photoacoustic cell.The wavelength modulation of the laser makes the measurement extremely selective also in difficult gas matrixes. With this technique the background signal is minimized resulting in low drifts and long calibration periods. For each application a suitable laser source can be selected.

 

Currently the LP1 can be equipped with near infrared tunable laser sources. The continuously increasing selection of lasers, e.g. quantum cascade lasers or infrared OPO lasers, will increase the range of measurable gases and also enhance the already high performance of the analyzer.

 

Example detection limits with NIR tunable DFB lasers

  • C2H2: 3 ppb
  • CO2: 3 ppb
  • CH4: 2 ppb
  • N2O: 20 ppb
  • HF: 0.4 ppb
  • HCN: 5 ppb
  • HCl: 20 ppb
  • NH3: 10 ppb
  • NO: 90 ppb
  • C2H4: 20 ppb
  • H2O2: 6 ppb
  • EtOH: 30 ppb
  • H2S: 20 ppb

(2xRMS, 60 second integration time)

 

Applications include

  • Gas impurities
  • Greenhouse gas monitoring
  • Air quality
  • Occupational safety
  • Process control
  • Automotive
  • Refrigerant leakage
  • Breath analysis
  • Safety and security
  • Natural gas and Syngas
  • Soil analysis

 

Features and specifications

  • Based on tunable laser photoacoustic spectroscopy with cantilever enhanced optical microphone
  • Configurable to several applications by selecting relevant laser sources
  • Response time user configurable from 5 seconds to several minutes
  • Simultaneous analysis of up to two gases
  • Low ppb detection limits
  • High selectivity
  • Low sample volume and wide dynamic range
  • Long re-calibration period
  • Built in 2-point sampling
  • User friendly calibration
  • Automatic compensation for temperature and pressure fluctuations
  • Versatile programming of analysis tasks
  • Built in high resolution graphical display with user friendly menus, no external computer required
  • Numerical and graphical presentation of the measurement results
  • No consumables & no moving parts

Brochures

LP1 product brochure


 

 

 

Digital brochure:

LP1 Laser-PAS Gas Analyzer - digital brochure